Detaljer på forslag

Forslagstitel på sprog (en): Fire resistance tests for device installations – Part 14: Partial penetration seals
Nummer:DSF/prEN 1366-14
Type:Forslag
Kilde:CEN
Udvalg:S-127
Udvalgsnavn:Bygningsbrandteknik
Forslag udgivet:11. apr 2024
Kommentarfrist:10. jun 2024
Antal kommentarer:0
Beskrivelse af forslaget:This part of the EN 1366 series specifies a method of test and criteria for the evaluation (including field of direct application rules) of the ability of a partial penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a device or devices that passes through one face of the element only. Partial penetration seals are used to seal apertures for electrical sockets, downlighters, media devices, cables and any item which requires an opening to be made in one face of the element of construction but does not include a device which passes through both faces. Supporting constructions are used in this part of the EN 1366 series to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice. This part of the EN 1366 series is used in conjunction with EN 1363 1. The purpose of a test described in this part of the EN 1366 series is to assess the integrity and insulation performance of the partial penetration seal, of the penetrating service(s) or device(s) and of the separating element in the surrounding area of the partial penetration seal. Where partial penetration seals are installed in ceilings and floors, the loadbearing capacity shall also be considered. No information can be implied by the test concerning the influence of the inclusion of such penetrations and penetration seals on the loadbearing capacity of walls. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only to be noted in the test report in describing the general behaviour of test specimens during the test. Tests in accordance with this part of the EN 1366 series are not intended to supply any information on the ability of the partial penetration seal to withstand stress caused by movements or displacements of the penetrating devices. The risk of spread of fire downwards cannot be assessed with this test. Tests in accordance with this part of the EN 1366 series do not address any risks associated with leakage of dangerous liquids or gases caused by failure of the device in case of fire.

Du kan kommentere på alle dele af dette dokument. Forslag vises i ét af to formater:

PDF-version
HTML-version

Hvis du ser indholdsfortegnelsen i venstre side, er det HTML-formatet. For at kommentere skal du åbne de enkelte afsnit ved at klikke på afsnittet i indholdsfortegnelsen.

Hvis du i stedet bliver bedt om at downloade et dokument, er det PDF-formatet. Du skal åbne dokumentet i et separat vindue og derefter kommentere ved at angive afsnitsnummer eller -tekst i "Sektion". Der er mere vejledning, når du har klikket på "Læs forslag".

For at afsende kommentar til Dansk Standard, skal du klikke på "Send kommentar" for det aktuelle afsnit.. Hvis du ønsker at arbejde videre med dine kommentarer, skal du i stedet klikke på "Gem kommentar til senere redigering".

Du kan tilføje og ændre i gemte kommentarer, men hvis du sender kommentaren, kan du ikke vende tilbage for at redigere.

Hvis du har gemte kommentarer, som ikke er afsendt, vil du, før høringsperioden udløber, blive mindet om, at du har ikke-afsendte kommentarer.